Sıcaklık ve Nem Test Cihazı
Dijital Termometre Ve Higrometre
■ Simultaneously displays temperature, humidity and time together with the function of indicating human body-comfort
■ Function of alarm setting
■ Range: Indoor temperature:-30℃~50℃(-22℉~+122℉);
Outdoor temperature: -50℃~70℃(-58℉~+158℉)
Humidity:20%~90%
■ Resolution:Temperature:0.1℃; Humidity:1%
■ Power:one 7# Alkalinebattery
■ Size:BGD 945---111×101×21.5(mm);BGD 946---115×64×19(mm)
■ Screen Size:BGD 945---81.5×64.5(mm);BGD 946--- 63×43(mm)
Infrared Thermometer
Ordering Information → Technical Item ↓ |
BGD 950/1 |
BGD 950/2 |
BGD 950/3 |
Range |
-50~380℃ |
-50~700℃ |
-50~1000℃ |
Distance to Spot Size (D:S) |
12:1 |
10:1 |
30:1 |
Emissivity |
0.95 |
0.95 |
0.1~1.0step step |
Accuracy |
±1.5% |
±1.0% |
|
Response Time |
<1second |
<150 millisecond |
|
Resolution |
0.1℃ |
0.1℃ |
|
Laser Type |
Single Laser |
Dual Laser |
|
Size |
160×82×42 mm |
146 ×104×43 mm |
|
Weight |
177g |
163g |
Sıcaklık Ve Nem Ölçer
■ Air Temperature:-30~100℃(Accuracy:±1℃~±1.5℃)
■ Relative Humidity: 0~100%RH(Accuracy:±2%RH~±4%RH)
■ Dew Point Temperature:-30~100℃(Caculated by measuring relative humidity and air temperature)
■ Wet Bulb Temperature:0~80℃(Caculated by measuring relative humidity and air temperature)
■ Absolute Humdity:0~500g/mm3, 0~218.5gr/ft3(Caculated by measuring relative humidity and air temperature)
■ Response Time:<15 seconds
■ Power Suppy:9V battery(work for 48 hours)
■ Size/Weioght:300*75*50 mm/400g
Temperature Tracker
Ordering Information → Technical Item ↓ |
One-Channel |
Four-Channel |
Seven-Channel |
||
BGD 951 |
BGD 954/1 |
BGD954/2 |
BGD 957/1 |
BGD 957/2 |
|
Number of Channels |
1 |
4 |
4 |
7 |
7 |
Temperature range |
-100℃~300℃ |
-100℃~300℃ |
-100℃~500℃ |
-100℃~300℃ |
-100℃~500℃ |
Duration |
45min for 200 ℃ 60min for 150℃ |
60min for 300℃ 120min for 150℃ |
60min for 500℃ 120min for 300℃ |
60 min for 300℃ 120 min for 200℃ |
60min for 500℃ 120 min for 300℃ |
Division |
0.1℃ |
0.1℃ |
0.3℃ |
0.5℃ |
|
Accuracy |
0.5% |
0.5% |
0.5% |
||
Storage |
Can store 32,000 readings. Record per seconds for 5 hours |
Every channel can store 16,000 readings. Record per seconds for 5 hours |
Record per seconds for 4 hours |
Record per seconds for 3 hours |
|
Sampling period |
1s, 10s |
1s, 2s, 3s, 4s, 5s, 6s, 10s, 20s, 30s, 1min programmable |
1s, 2s, 3s, 5s, 8s、10s、12s, 20s,40s, 60s programmable |
||
Setting Software |
①Can select sampling period ②Print the Tem.Curve with Computer ③Check the data with EXCEL |
① Can select sampling period ② Show the real-time Tem.curve ③ Can save many groups data’s
|
① Can select any channel seperately ② Calibrate each channel seperately③ Can select sampling period
|
||
Analysis software |
No |
① Display Tem. data’s; ② Calculate heating rate between tow Tem.leverl ③ Calculate total time above two different Tem ④ Calculate peak Tem. ⑤ Compare different Tem. profile; ⑥ Print Report |
|||
Standard Disposition |
◆ Oven datalogger |
◆ Oven datalogger ◆USB cable ◆Setting software and Analysis software ◆ Insulation box ◆Manual |
◆ Oven datalogger ◆USB cable ◆Setting software and Analysis software ◆ Insulation box ◆Manual |
||
Size |
Φ 63 ×160mm |
110×125×300mm |
135×155×300mm |
100×120×280mm |
130×160×300mm |